Sample Pad / Glass Fiber / Conjugate Pad

Category:

We Are Offering The Finest And Purified Biomarker For Unique Sensitivity And Specificity For Immuno Chromatographic Assay

Description

Sample Pad or Glass Fiber

A sample pad can be used for urine, whole blood, saliva and serum specimen. This is a specially treated pad that enhances releasing capacity of your assay analytes and low retention volume of the analytes to provide you the ultra-sensitive test result.

Conjugate Pad

Conjugate pads can perform multiple tasks, the most important of which is the uniform transfer of detection reagents and test samples to the membrane. When the sample flows into the conjugate pad, the detection reagent dissolves, lifts the pad material, and moves into the membrane together with the sample. The important function of the conjugate pad is to deliver the test agent particles as a constant volume of sample on each test strip to the membrane.

Conjugate Pad / Sample Pad

Sr. No. Item Note Thickness (mm) Climbing Speed (mm/60s) Water-Holding Capacity (g/m2) Model
1 Sample Pad Hydrophobic, Required treatment before use 0.24-0.36 <15 400-600 GF-AA-60c
2 Sample Pad 0.32-0.48 <15 550-800 GF-AB-80c
3 Soaking Conjugate Pad These fibers have the characterisitics of smooth surface, uniform fiber testure, uniform thickness and so on. 0.20-0.28 15-40 200-400 GF-BA-05
4 Sample Pad, Conjugate Pad 0.24-0.36 15-32 400-600 GF-AA-60
5 Sample Pad, Conjugate Pad 0.32-0.48 15-32 550-800 GF-AB-80
6 Sample Pad, Conjugate Pad 0.19-0.29 20-45 300-500 GF-BA-54
7 Sample Pad, Conjugate Pad 0.25-0.35 20-45 500-700 GF-BB-56
8 Whole Blood Filter Paper Adopt micro glass fiber with diameter 0.6-3nm, with a good hydrophilicity. 0.25-0.35 30-50 400-550 GF-BS-30
9 Whole Blood Filter Paper 0.41-0.51 30-50 550-700 GF-BS-04
10 Whole Blood Filter Paper 0.45-0.55 30-50 600-800 GF-BS-05
11 Whole Blood Filter Paper GF-BS-35
12 Whole Blood Filter Paper GF-BS-35A
13 Conjugate Pad Good Hydrophillicity after having Treatment,Well arrayed,evebly and fine in texture. Fibrous Membrane Component is biological Inert and having influence on normal reflection of bioactivator. 0.37-0.a53 20-160 480-680 PE-AA-42
14 Sample Pad, Conjugate Pad (Treatment Not Required) 0.18-0.26 Oct-40 170-270 PE-BA-87
15 Sample Pad, Conjugate Pad (Treatment Not Required) 0.25-0.35 15-40 220-320 PE-BB-89
16 Conjugate Pad Hydrophobic, Required treatment before use 0.36-0.39 14 to 35 (Sec/4cm) PE-CA-05/CT1
17 Conjugate Pad 0.42-0.46 24 + 15 (Sec/4cm) PE-DA-03/CT1
18 Sample Pad 0.36-0.39 14 to 35 (Sec/4cm) PE-CB-05/ST1
19 Sample Pad 0.42-0.46 24 + 15 (Sec/4cm) PE-CC-05/ST2